Topic 2

Finding E°cell

Each half-cell has an electrode potential, its tendency to be reduced. It cannot be measured alone, so it is measured against the standard hydrogen electrode, which is given 0.00 V. Standard means 1 M solutions, 1 bar gas pressure and usually 298 K, written with a ° sign.

Tables list standard reduction potentials. The more negative the value, the more easily the metal is oxidised, so in a cell the electrode with the lower E° becomes the anode. The cell voltage is the difference.

E°cell = E°cathode − E°anode

both values are reduction potentials, used as printed in the table

Predict first

E° for Zn²⁺/Zn is −0.76 V and for Ag⁺/Ag is +0.80 V. What is E°cell for a cell made from these two electrodes?

Build a cell from two electrodes

First electrode

Second electrode

E° (V), reductionMg²⁺/Mg−2.36Zn²⁺/Zn−0.76Fe²⁺/Fe−0.44H⁺/H₂0.00Cu²⁺/Cu+0.34Ag⁺/Ag+0.801.10 V

Blue: anode, the lower E°, oxidised. Orange: cathode, the higher E°, reduced.

E°cell = E°cathode − E°anode
1.10 V
electrons n
2
ΔG° = −nFE°cell
-212.3 kJ mol⁻¹

Zn + Cu²⁺ → Zn²⁺ + Cu

A positive E°cell means the reaction runs by itself. The link to free energy is ΔG° = −nFE°cell, where n is the number of electrons transferred and F = 96500 C mol⁻¹ is the Faraday constant. For the Daniell cell, n = 2: ΔG° = −2 × 96500 × 1.10 = −212300 J, or −212.3 kJ mol⁻¹.

ΔG° = −n F E°cell